{"id":897,"date":"2023-01-17T15:16:06","date_gmt":"2023-01-17T20:16:06","guid":{"rendered":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/?page_id=897"},"modified":"2023-01-31T12:07:53","modified_gmt":"2023-01-31T17:07:53","slug":"leica-stellaris-8-dive-system-specs","status":"publish","type":"page","link":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/","title":{"rendered":"Leica DIVE Multiphoton System Specs"},"content":{"rendered":"\n<table id=\"tablepress-8\" class=\"tablepress tablepress-id-8\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Microscope platform<\/td><td class=\"column-2\">Stellaris 8<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Illumination<\/td><td class=\"column-2\">WLL: 440 - 790 nm<br \/>\n405nm<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Pulsed laser<\/td><td class=\"column-2\">Chameleon Vision-S<br \/>\n73fs pulse width<br \/>\n690 -1050 nm<br \/>\n&gt; 400 kW peak power near 800 nm<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Dichroics<\/td><td class=\"column-2\">RF 670<br \/>\nRF 750<br \/>\nRF 795 (available upon request)<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">4-channel spectral detection<\/td><td class=\"column-2\">3x HyD S<br \/>\n1x HyD X<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">2-channel 4Tune spectral detection<\/td><td class=\"column-2\">4Tune HyD RLD<br \/>\n4Tune HyD RLD <\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Objectives<\/td><td class=\"column-2\">HC PL APO 10x\/0.40<br \/>\nHC PL APO 20x\/0.75 <br \/>\nHC PL APO 63x\/1.40 Oil<br \/>\nHC PL IRAPO 20\/0.75 W (available upon request)<br \/>\nHC FLUOTAR L 25x\/0.95 W VISIR (available upon request)<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Software<\/td><td class=\"column-2\">LAS X 3D Visualisation<br \/>\nLightning <br \/>\nAivia Apex<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-8 from cache -->\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":710,"featured_media":0,"parent":12,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":"","_links_to":"","_links_to_target":""},"tags":[],"class_list":["post-897","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Leica DIVE Multiphoton System Specs - Advanced Microscopy Facility<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Leica DIVE Multiphoton System Specs - Advanced Microscopy Facility\" \/>\n<meta property=\"og:url\" content=\"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/\" \/>\n<meta property=\"og:site_name\" content=\"Advanced Microscopy Facility\" \/>\n<meta property=\"article:modified_time\" content=\"2023-01-31T17:07:53+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/equipment\\\/leica-stellaris-8-dive-system-specs\\\/\",\"url\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/equipment\\\/leica-stellaris-8-dive-system-specs\\\/\",\"name\":\"Leica DIVE Multiphoton System Specs - Advanced Microscopy Facility\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/#website\"},\"datePublished\":\"2023-01-17T20:16:06+00:00\",\"dateModified\":\"2023-01-31T17:07:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/equipment\\\/leica-stellaris-8-dive-system-specs\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/equipment\\\/leica-stellaris-8-dive-system-specs\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/equipment\\\/leica-stellaris-8-dive-system-specs\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Equipment\",\"item\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/equipment\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Leica DIVE Multiphoton System Specs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/#website\",\"url\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/\",\"name\":\"Advanced Microscopy Facility\",\"description\":\"University of Virginia School of Medicine\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/med.virginia.edu\\\/advanced-microscopy-facility\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Leica DIVE Multiphoton System Specs - Advanced Microscopy Facility","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/","og_locale":"en_US","og_type":"article","og_title":"Leica DIVE Multiphoton System Specs - Advanced Microscopy Facility","og_url":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/","og_site_name":"Advanced Microscopy Facility","article_modified_time":"2023-01-31T17:07:53+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/","url":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/","name":"Leica DIVE Multiphoton System Specs - Advanced Microscopy Facility","isPartOf":{"@id":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/#website"},"datePublished":"2023-01-17T20:16:06+00:00","dateModified":"2023-01-31T17:07:53+00:00","breadcrumb":{"@id":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/leica-stellaris-8-dive-system-specs\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/"},{"@type":"ListItem","position":2,"name":"Equipment","item":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/equipment\/"},{"@type":"ListItem","position":3,"name":"Leica DIVE Multiphoton System Specs"}]},{"@type":"WebSite","@id":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/#website","url":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/","name":"Advanced Microscopy Facility","description":"University of Virginia School of Medicine","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/pages\/897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/users\/710"}],"replies":[{"embeddable":true,"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/comments?post=897"}],"version-history":[{"count":4,"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/pages\/897\/revisions"}],"predecessor-version":[{"id":947,"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/pages\/897\/revisions\/947"}],"up":[{"embeddable":true,"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/pages\/12"}],"wp:attachment":[{"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/media?parent=897"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/med.virginia.edu\/advanced-microscopy-facility\/wp-json\/wp\/v2\/tags?post=897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}