{"id":12,"date":"2015-07-04T22:41:07","date_gmt":"2015-07-05T02:41:07","guid":{"rendered":"http:\/\/cores.med.virginia.edutest-replo\/cost-analysis\/"},"modified":"2024-10-17T09:18:16","modified_gmt":"2024-10-17T13:18:16","slug":"equipment","status":"publish","type":"page","link":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/","title":{"rendered":"Equipment"},"content":{"rendered":"<p>The Biomolecular Analysis Facility has equipment which is either not commonly found in individual laboratories or is needed only occasionally by some laboratories. Some equipment is operated by facility personnel, and some is used by individual researchers.<\/p>\n<p>For more information: contact Nicholas Sherman ph. 924-0070<\/p>\n<h4><a href=\"https:\/\/med.virginia.edu\/core-facilities\/cores-2\/biomolecular-analysis-facility-resource-statement\/\">Statement of resources for grant applications<\/a><\/h4>\n<p>&nbsp;<\/p>\n<p>\u200b<\/p>\n<table id=\"table-zebra-one\">\n<tbody>\n<tr>\n<th style=\"width: 69%\">TYPE OF EQUIPMENT<\/th>\n<th style=\"width: 29%\">IMAGE<\/th>\n<\/tr>\n<tr>\n<td>\n<h3>Thermo Scientific Q Exactive HF-X<\/h3>\n<p>We have four methods of loading samples into this instrument:<\/p>\n<ul>\n<li>infusion pump (no fractionation)<\/li>\n<li>Capillary electrophoresis<\/li>\n<li>nano UHPLC-flow rates of nnn for 75 \u00b5m diamater columns<\/li>\n<li>UHPLCs with flow rates up to 1 ml\/min for larger columns<\/li>\n<\/ul>\n<p>The mass spectrometer has an Orbitrap mass analyzer with a mass range of 50 to 8000, and resolution up to 240,000.<\/p>\n<p>&nbsp;<\/td>\n<td valign=\"bottom\"><a href=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-1554\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290-300x191.jpg\" alt=\"q-exactive machine\" width=\"300\" height=\"191\" srcset=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290-300x191.jpg 300w, https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290.jpg 456w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td valign=\"bottom\"><\/td>\n<\/tr>\n<tr>\n<td>\n<h3>Bruker MicroFlex MALDI<\/h3>\n<p>This instrument measures masses of intact molecules. Sample preparation is usually relatively simple so this instrument is the first choice to obtain the mass of peptides, proteins and some other molecules.<\/td>\n<td valign=\"bottom\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-771 size-full\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/bruker_MALDI.jpg\" alt=\"bruker MALDI time of flight mass spectrometer\" width=\"200\" height=\"276\" \/><\/td>\n<\/tr>\n<tr>\n<td>\n<h3>Molecular Dynamics Gemini EM SpectraMax <a title=\"Fluorescent plate reader\" href=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/services\/shared-instrumentation\/fluorescent-plate-reader\/\">Fluorescent plate reader<\/a><\/h3>\n<ul>\n<li>For fluorescence readings of plates with 384, 96, 24, 12, 6 well microtiter plates.<\/li>\n<li>Dual monochromator optics.<\/li>\n<li>Does not perform absorbance readings.<\/li>\n<li>Operated by researcher. Fee for use.<\/li>\n<\/ul>\n<\/td>\n<td valign=\"bottom\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-768 size-full\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/plate-reader.jpg\" alt=\"fluorescence plate reader\" width=\"250\" height=\"96\" \/><\/td>\n<\/tr>\n<tr>\n<td>\n<h3>High performance liquid chromatography.<\/h3>\n<ul>\n<li>Dionex Ultimate for 0.3 to 4.6 mm diameter columns.<\/li>\n<\/ul>\n<p>Variable wavelength UV detector.Used for separation of peptides, proteins and some other molecules, usually with reverse phase columns.<\/td>\n<td valign=\"bottom\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-779 size-medium\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/DionexHPLC-193x300.jpg\" alt=\"Dionex HPLC\" width=\"193\" height=\"300\" srcset=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/DionexHPLC-193x300.jpg 193w, https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/DionexHPLC.jpg 250w\" sizes=\"(max-width: 193px) 100vw, 193px\" \/><\/td>\n<\/tr>\n<tr>\n<td>\n<h3>JASCO J-1500 Circular dichroism spectropolarimeter<\/h3>\n<p>For studies on tertiary structure of proteins.<br \/>\nOperated by researcher. Fee for use.<br \/>\nBrief background on operation <a title=\"Circular dichroism\" href=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/circular-dichroism\/\">here<\/a>.<\/td>\n<td valign=\"bottom\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-1575\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/JASCO-CD-768x611-300x239.jpg\" alt=\"\" width=\"300\" height=\"239\" srcset=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/JASCO-CD-768x611-300x239.jpg 300w, https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/JASCO-CD-768x611.jpg 768w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td valign=\"bottom\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td valign=\"bottom\"><\/td>\n<\/tr>\n<tr>\n<td>\n<h3 class=\"internal-link\">Molecular interactions<\/h3>\n<p><a class=\"internal-link\" href=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/services\/shared-instrumentation\/molecular-interactions\/\">fort\u00e9BIO Octet RED96<\/a> uses BioLayer Interferometry with disposable probes to measure association and dissociation rates of pairs of molecules and hence dissociation constants.<br \/>\nThis instrument can perform 8 simultaneous readings. It can also perform quantitation measurements including some equivalent to ELISA,<\/td>\n<td valign=\"bottom\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-781 size-full\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/Octet-250.jpg\" alt=\"fort\u00e9BIO Octet\" width=\"250\" height=\"236\" \/><\/td>\n<\/tr>\n<tr>\n<td>\n<h3><a class=\"internal-link\" href=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/shared-intrumentation\/real-time-cell-analysis\/\">Acea RTCA cell analysis instrument<\/a><\/h3>\n<p>real time, continuous measurement of cellular activity, including migration, based on impedance measurements<\/td>\n<td valign=\"bottom\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-783 size-full\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/RTCA.jpg\" alt=\"ACEA RTCA instrument\" width=\"250\" height=\"148\" \/><\/td>\n<\/tr>\n<tr>\n<td>\n<h3><a href=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/shared-intrumentation\/absorbance-plate-reader\/\">Biotek ELx800 absorbance plate reader<\/a><\/h3>\n<p>absorbance measurements on microtiter plates at 450, 562, 600, 660 nm<\/td>\n<td valign=\"bottom\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-777 size-full\" src=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2015\/10\/Absorbancereader.jpg\" alt=\"BioTek Absorbance reader\" width=\"250\" height=\"180\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The Biomolecular Analysis Facility has equipment which is either not commonly found in individual laboratories or is needed only occasionally by some laboratories. Some equipment is operated by facility personnel, and some is used by individual researchers. For more information: contact Nicholas Sherman ph. 924-0070 Statement of resources for grant applications &nbsp; \u200b TYPE OF [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":2,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":"","_links_to":"","_links_to_target":""},"tags":[],"class_list":["post-12","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Equipment - Biomolecular Analysis Facility<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Equipment - Biomolecular Analysis Facility\" \/>\n<meta property=\"og:description\" content=\"The Biomolecular Analysis Facility has equipment which is either not commonly found in individual laboratories or is needed only occasionally by some laboratories. Some equipment is operated by facility personnel, and some is used by individual researchers. For more information: contact Nicholas Sherman ph. 924-0070 Statement of resources for grant applications &nbsp; \u200b TYPE OF [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/\" \/>\n<meta property=\"og:site_name\" content=\"Biomolecular Analysis Facility\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-17T13:18:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290-300x191.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/\",\"url\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/\",\"name\":\"Equipment - Biomolecular Analysis Facility\",\"isPartOf\":{\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290-300x191.jpg\",\"datePublished\":\"2015-07-05T02:41:07+00:00\",\"dateModified\":\"2024-10-17T13:18:16+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#primaryimage\",\"url\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290.jpg\",\"contentUrl\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290.jpg\",\"width\":456,\"height\":290,\"caption\":\"q-exactive machine\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Equipment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/#website\",\"url\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/\",\"name\":\"Biomolecular Analysis Facility\",\"description\":\"University of Virginia School of Medicine\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Equipment - Biomolecular Analysis Facility","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/","og_locale":"en_US","og_type":"article","og_title":"Equipment - Biomolecular Analysis Facility","og_description":"The Biomolecular Analysis Facility has equipment which is either not commonly found in individual laboratories or is needed only occasionally by some laboratories. Some equipment is operated by facility personnel, and some is used by individual researchers. For more information: contact Nicholas Sherman ph. 924-0070 Statement of resources for grant applications &nbsp; \u200b TYPE OF [&hellip;]","og_url":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/","og_site_name":"Biomolecular Analysis Facility","article_modified_time":"2024-10-17T13:18:16+00:00","og_image":[{"url":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290-300x191.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/","url":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/","name":"Equipment - Biomolecular Analysis Facility","isPartOf":{"@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/#website"},"primaryImageOfPage":{"@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#primaryimage"},"image":{"@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#primaryimage"},"thumbnailUrl":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290-300x191.jpg","datePublished":"2015-07-05T02:41:07+00:00","dateModified":"2024-10-17T13:18:16+00:00","breadcrumb":{"@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#primaryimage","url":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290.jpg","contentUrl":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-content\/uploads\/sites\/330\/2019\/01\/ThreeColumnLeft_BiomolecularAnalysisFacility_456x290.jpg","width":456,"height":290,"caption":"q-exactive machine"},{"@type":"BreadcrumbList","@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/equipment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/"},{"@type":"ListItem","position":2,"name":"Equipment"}]},{"@type":"WebSite","@id":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/#website","url":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/","name":"Biomolecular Analysis Facility","description":"University of Virginia School of Medicine","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/pages\/12","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/comments?post=12"}],"version-history":[{"count":10,"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/pages\/12\/revisions"}],"predecessor-version":[{"id":1988,"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/pages\/12\/revisions\/1988"}],"wp:attachment":[{"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/media?parent=12"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/med.virginia.edu\/biomolecular-analysis-facility\/wp-json\/wp\/v2\/tags?post=12"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}