Skip to main content
Joseph V Rispoli

Joseph V Rispoli

Associate Professor, Radiology and Medical Imaging

Primary Phone Number

Bio & Overview

  • Magnetic resonance imaging
  • Radiofrequency hardware
  • Computational modeling

Academic Information

Department
Radiology and Medical Imaging

Primary Education

  • B.S., Computer engineering, University of Virginia, 2002
  • B.S., Electrical engineering, University of Virginia, 2002
  • Ph.D., Biomedical engineering, Texas A&M University, 2015

Research Interests

Medical Imaging

Research Disciplines

  • Biomedical Engineering
  • Electrical and Computer Engineering

Selected Publications

Selected Publications

Ramesh, T. V., Narongrit, F. W., & Rispoli, J. V. (2025). Adaptable, wearable, and stretchable coils: A review. MAGNETIC RESONANCE IN MEDICINE, 93(5), 2186-2208. doi:10.1002/mrm.30428

Narongrit, F. W., Vishnu Ramesh, T., & Rispoli, J. V. (2024). Stretching the Limits of MRI-Stretchable and Modular Coil Array Using Conductive Thread Technology. IEEE ACCESS, 12, 89613-89620. doi:10.1109/ACCESS.2024.3416869

Narongrit, F. W., Ramesh, T. V., & Rispoli, J. V. (2024). An Open Source 16-Channel Breast Array for Prone and Supine MRI. IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 8(3), 251-258. doi:10.1109/JERM.2024.3396697

Narongrit, F. W., Ramesh, T. V., & Rispoli, J. V. (2023). Parametric Design of a 3D-Printed Removable Common-Mode Trap for Magnetic Resonance Imaging. 2023 IEEE MTT-S IMBIOC, 127-129. doi:10.1109/IMBIOC56839.2023.10304882

Ramesh, T. V., Narongrit, F. W., Susnjar, A., & Rispoli, J. V. (2023). Stretchable receive coil for 7T small animal MRI. JOURNAL OF MAGNETIC RESONANCE, 353. doi:10.1016/j.jmr.2023.107510

Vike, N., Bari, S., Susnjar, A., Lee, T., Lycke, R., Auger, J., . . . Rispoli, J. (2022). American Football Position-Specific Neurometabolic Changes in High School Athletes: A Magnetic Resonance Spectroscopic Study. JOURNAL OF NEUROTRAUMA, 39(17-18), 1168-1182. doi:10.1089/neu.2021.0186

De Zanche, N., van den Berg, C., Brunner, D., Murphy-Boesch, J., Rispoli, J., et al. (2022) ISMRM best practices for safety testing of experimental RF hardware. ISMRM White Paper. doi: 10.7939/r3-7vpe-x737 

Liu, S., Wu, D., Sun, X., Fan, Y., Zha, R., Jalali, A., . . . Yokota, H. (2021). Overexpression of Lrp5 enhanced the anti-breast cancer effects of osteocytes in bone. BONE RESEARCH, 9(1). doi:10.1038/s41413-021-00152-2

Zou, Y., Zhu, W., Yang, H. -C., Jang, I., Vike, N. L., Svaldi, D. O., . . . Rispoli, J. V. (2021). Development of brain atlases for early-to-middle adolescent collision-sport athletes. SCIENTIFIC REPORTS, 11(1). doi:10.1038/s41598-021-85518-6

Li, X., Pan, J. W., Avdievich, N. I., Hetherington, H. P., & Rispoli, J. V. (2021). Electromagnetic simulation of a 16-channel head transceiver at 7 T using circuit-spatial optimization. MAGNETIC RESONANCE IN MEDICINE, 85(6), 3463-3478. doi:10.1002/mrm.28672

Vincent, J. M., & Rispoli, J. V. (2020). Conductive Thread-Based Stretchable and Flexible Radiofrequency Coils for Magnetic Resonance Imaging. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 67(8), 2187-2193. doi:10.1109/TBME.2019.2956682

Hopkins, K. A., Vike, N., Li, X., Kennedy, J., Simmons, E., Rispoli, J., & Solorio, L. (2019). Noninvasive characterization of in situ forming implant diffusivity using diffusion-weighted MRI. JOURNAL OF CONTROLLED RELEASE, 309, 289-301. doi:10.1016/j.jconrel.2019.07.019

Li, X., & Rispoli, J. V. (2019). Toward 7T breast MRI clinical study: safety assessment using simulation of heterogeneous breast models in RF exposure. MAGNETIC RESONANCE IN MEDICINE, 81(2), 1307-1321. doi:10.1002/mrm.27395

Bari, S., Svaldi, D. O., Jang, I., Shenk, T. E., Poole, V. N., Lee, T., . . . Talavage, T. M. (2019). Dependence on subconcussive impacts of brain metabolism in collision sport athletes: an MR spectroscopic study. BRAIN IMAGING AND BEHAVIOR, 13(3), 735-749. doi:10.1007/s11682-018-9861-9

Rispoli, J. V., Dimitrov, I. E., Cheshkov, S., Malloy, C., Wright, S. M., & McDougall, M. P. (2016). Trap design and construction for high-power multinuclear magnetic resonance experiments. CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 46(4), 162-168. doi:10.1002/cmr.b.21345

McDougall, M. P., Cheshkov, S., Rispoli, J., Malloy, C., Dimitrov, I., & Wright, S. M. (2014). Quadrature Transmit Coil for Breast Imaging at 7 Tesla Using Forced Current Excitation for Improved Homogeneity. JOURNAL OF MAGNETIC RESONANCE IMAGING, 40(5), 1165-1173. doi:10.1002/jmri.24473